9. Monitor "No Diving" markers throughout season in areas that are painted in fade over season, repair as needed. "No Diving" markers must be 4" in letter height. 16. monitor fence post next the the building that is beginning to lean away from building. gaps greater than 4" will need to be shielded.
The free chlorine level was a 0ppm at start of inspection. Operator was able to adjust and now the free chlorine level in 10ppm. Monitor and make sure it is a minimum of 1ppm.
6.0
General Comments
Flow ~60GPM
**Keep daily written records of free chlorine, pH and main drain checks. **Keep weekly records of total alkalinity and cyanuric acid levels.
One surface skimmer was missing a weir-operator was able to repair.
4.0
9.
The 'NO DIVING' tile markers are not 4" in height. Sharpie used to add height in lettering so now they are 4".
4.0
19.
Sign stating the following in 1" letters was not available. A sign stating "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" and "ADULTS SHOULD NOT SWIM ALONE" was created and attached to fence, in 1" letters. CDI
Can see were extended no diving tiles to meet regulation length. Some tiles can see the marker is starting to rub off/fade Monitor and remark as needed. NO DIVING needs to be 4 inches tall. The ones that are fading are the ones located at the mushroom area of the pool mostly.
NO DIVING markers on deck were 3 15/16" tall. Letters must be 4" total height. Letters were extended to greater than 4" by permanent marker. Maintain 4" throughout the season. CDI
4.0
12.
One inlet fitting was missing. Replaced by end of inspection. CDI
4.0
16.
New fence was installed. It was greater than 2" off the ground in several locations. Fence panels were lowered. One gate had area that was greater than 2" on one side. Gate was repaired by end of inspection. CDI
4.0
General Comments
Permit issued. Follow executive orders. No night swimming.