The fence does not meet the current code of .2528(a). It was constructed prior to 2010. Recommend bringing the current fence up to compliance with .2528 (a): 48' in height minimum, no more then 4' between vertical members, etc
4.0
24.
Flow meter is maxing out at 120 GPM and flow is over that. The maximum pump flow is 160GPM and the main drains are rated for 188GPM. Due to age of pool and main drains capable of flow > pump, recommend replacing the flow meter with one that can handle and read the actual flow.
The fence does not meet the current code of .2528(a). It was constructed prior to 2010. Recommend bringing the current fence up to compliance with .2528 (a): 48" in height minimum, no more then 4" between vertical members, etc.
4.0
General Comments
Ventilation fan must run at all times in the chemical storage room.
Ring buoy rope was too long. Rope for ring buoy is to be 42` long. Operator fixed rope to correct length.
6.0
16.
Areas of fence less than 48 inches. Fence was constructed prior to 2000. Does not comploy with .2528(a) Recommend repair but not required.
4.0
24.
Flow meter in pump room was maxing out on readable gpm. Max pump flow is 160gpm which is less then gpm rating of main drains which is 188gpm. Operator said a new meter has been ordered so it will properly read.
Areas of fence less than 48 inches. Fence was constructed prior to 2000. Does not comploy with .2528(a) Recommend repair but not required.
4.0
22.
Upon inspection, phone was not working. Operator was able to get a new phone and it was properly working.
6.0
24.
Flow meter in pump room was maxing out on readable gpm. Max pump flow is 160gpm which is less then gpm rating of main drains which is 188gpm. Flow meter needs to be replaced.
4.0
General Comments
Ring buoy in good repair but should be replaced before end of season due to signs of rope wearing.
Ph greater than 8.0. Acid was added at inspection to lower pH.
6.0
6.
Equalizer lines under the skimmer are open on both the pool wall and in the skimmer basket. If this equalizer line is open it must have a VGB compliant cover. Plugs can be placed on both ends of the pipe. If all water is removed from the pipe and plugs placed on both ends. pool permit may not be issued until the suction hazard is rectified.
6.0
11.
Replace rubber bumpers on the pool ladder feet.
2.0
16.
Areas of fence less than 48 inches. Fence was constructed prior to 2000. Does not comploy with .2528(a) Recommend repair but not required.
There are areas of the fence that are less then 48", the retaining wall allows access over where it joins the white metal fence. Fence was constructed before 2000 and does not comply with .2528 (a). Due to this it is recommended to repair but not required.
4.0
24.
Flow meter not operating at start-unit removed and repaired. Flow meter is now operating. CDI
4.0
25.
Fan in the chemical storage room was not on at start- breaker switched on and now the fan is operating.
2.0
General Comments
*Add weekly cyanuric acid levels and weekly total alkalinity levels to the CPO records.
Pool may need to be repainted by next pool season. Beginning to wear. Ring buoy is starting to show signs of wear. Replace once it becomes worn beyond use.
Ladder on the 5ft side that is by the building is missing one of the rubber bumpers at the bottom. Replace rubber piece. Operator going to pool store to get new rubber piece to replace.
One weir was missing in the skimmer and was replaces by operator at inspection.
4.0
11.
Handrail on ladder at the 5' depth marker is loose. tighten all ladders and have rubber bumpers in place on ladder feet.
2.0
General Comments
3. pH is 7.8. Monitor and keep pH within 7.2-7.8 range. 5. CPO is no longer at establishment and stopped recording pool chemistry on 7/6/19. 7/7 and 7/8 chemical readings were not recorded. Maintain daily written records. new CPO provided certification. 16. Fence on top retaining wall is not 48" high. Recommend to replace with compliant fence.
Make sure weekly readings of total alkalinity and cyanuric acid levels are taken
4.0
15.
New ring buoy was installed, but rope was tied a little to short. Rope was retied at proper length.CDI
6.0
16.
New gate was installed, it is solid. Make sure there is enough spring tension to keep gate self closing when wind blows. Fence on top retaining wall is not 48" high. Recommend to replace with compliant fence.
Fence on top of retaining wall is not 48" high. Due to date pool was constructed, pool can operate. Recommend replacing fence with correct one. Fence entry gate had diagonal support. This support creates a potential climbing hazard. A sign was placed in front of diagonal support.
One inlet (at 5' end away from building) is cracked. Replace inlet cover that is cracked by 08/17/18.
4.0
15.
Ring buoy rope was too short (approx. 2ft) and deteriorating. Rope must be 1.5 times the width of pool. Rope replaced by end of inspection. CDI
6.0
16.
Fence on top of retaining wall is not 48" high. Recommend to replace with compliant fence.
4.0
17.
One spot (at 5' end away from building) has concrete that is chipped away creating a trip hazard. Repair this area so it is flat by 08/17/18 or before.
The gate had a area where the distance from grade level to the bottom of the gate was greater than 2 inches. Pool management was notified and repaired gate bringing into compliances defined in 15A.NCAC-18A.2528(a). One side of the pool has a retaining wall with a chain link fence as the top barrier. The fence is less than 48 inches. Replacement with a fence > or = 48 inches tall is required however, pool fence is in compliance with 15A NCAC.2528(c)
4.0
24.
The pool pump had a small leak. Pool management has ordered a part to make necessary repairs.
All safety equipment and signs in place. Emergency telephone works. Main drains secured. Contrasting color ban on steps is beginning to fade. May need painting before next seasons permitting.
pH in pool was 7.0 at the initial reading. Soda Ash was added and now 7.4
Must be between 7.2-7.8
6.0
5.
Keep weekly cyanuric acid and total alkalinity levels.
0.0
8.
Equalizer lines have been capped in skimmers. Must have approved covers on equalizer lines by 2011 operating season. Skimmer baskets on side by bldg. were full of leaves and debris-check and clean often.
Equalizer lines have been capped off in the skimmers. Covers have been installed on lines on pool wall but lines are still capped off. Hines Engineering certified pool VGB compliant with equalizers capped. Cannot uncap and use covers until pool is recertified by a registered design professional. Must have approved covers and letter by 2011 operating season.
4.0
General Comments
Pool closing at 8:00pm until more lights can be installed and measured. Must have 10fc of light on all areas of pool deck. Call before allowing night swimming 989-5186
Letter from Hines Engineering stating compliance with VGB received and approved.