Flow meter maxing out and not able to indicate actual gpm flow of circulation system. Replace unit with one that can read the circulation rate. The maximum pump flow does not exceed main drain rating.
4.0
25.
Chemicals should be stored in a separate locked room.
2.0
29.
Shower in female restroom was not operating - repair.
2.0
General Comments
Rope on ring buoy (outer ring) is showing wear. Operator ordered while in inspection. Replace when rope is in bad repair.
One skimmer is missing a weir- should be replaced for proper operation. Equalizer ports in the skimmer basket should be capped to prevent debris buildup.
4.0
24.
Flow meter was not working. Operator will replace.
4.0
25.
Chemicals should be stored in a separate locked room.
2.0
29.
Shower in female restroom was not operating - repair.
2.0
General Comments
Monitor deck joints-cannot have any offsets > 1/2". Repair if needed.
One skimmer is missing a weir- should be replaced for proper operation. Equalizer ports in the skimmer basket should be capped to prevent debris buildup.
4.0
24.
Flow meter is not able to indicate actual gpm flow as the bobber is maxing out on the actual readable GPM on meter. Replace unit with one that can read the circulation rate. The maximum pump flow does not exceed main drain rating.
4.0
25.
Chemicals should be stored in a separate locked room.
2.0
29.
Shower in female restroom was not operating - repair.
2.0
General Comments
-Screws added to windows so they cannot open >4". -Monitor deck joints-cannot have any offsets >1/2 inch. Repair if needed. -CPO sheet emailed that has the required daily and weekly items that must be repaired.
Bottom step on one of the ladders in the pool deep end is loose-Repair.
2.0
24.
Flow meter is not operational, bobber is maxing out on the readable GPM- replace unit with one that can read the GPM Flow. Maximum pump GPM does not exceed main drain rating.
4.0
25.
Chemicals should be stored in a separate locked room.
2.0
General Comments
*Equalizer ports in the skimmer basket should be capped* *Monitor deck joints-cannot have any offsets > 1/2 inch. Repair if needed.
Replace rubber bumper on pool ladder foot. maintain ladders in good repair.
2.0
General Comments
Pool motor has been inspected and signed off by building inspections. Pool may reopen. 7. Area of damage on the pool floor must be patched prior to permitting next season. Wading pool is closed by CPO for non functioning motor.
Pool ph is less than 7.2. Maintain pH between 7.2-7.8. pool closed due to pH. Call this office for reinspection after chemicals have been adjusted to correct range.
6.0
11.
Replace rubber bumper on pool ladder foot. maintain ladders in good repair.
2.0
24.
Pool pump/motor was replaced since pool permitting building inspections did not permit or inspect electrical work. pool must remain closed until building inspections has completed and singed off on pump/motor replacement. Contact johnston county building inspections to obtain permit/inspection of pump/motor.
Flower pot was blocking depth marker on fence. Flower pot was moved. Do not block depth marker. CDI
4.0
11.
Adjust ladder so that legs touch the wall. One leg missing end cap on ladder. Replace
2.0
25.
Chemicals should be in separate room
2.0
General Comments
Chemical feeder may be damaged, it is not pumping. I unplugged it until operator can verify it is working properly. Pressure switch must be checked also. If not working properly, repair/replace or install erosion feeder. Cannot hand feed or put chlorine tabs in skimmers.
Hand rail at the three foot entrance into the pool is loose.
2.0
25.
Chemicals should be stored in a separate locked storage room.
2.0
General Comments
Main drains secured. Required safety equipment and signage in place. Emergency telephone has been fixed and now gives the correct telephone number on the 911 system.
Hand rail loose at the three foot entrance to the pool.
2.0
25.
Chemicals should be stored in a separate locked room.
2.0
General Comments
Main drains secured. All safety and required signage in place. Emergency telephone gives the right address, but the telephone number for the pool does not show up on 911's end. Must be corrected in the next couple of days or permit action will be taken.
By next pool season, repaint or patch all aareas in pool that is peeling.
4.0
16.
Repair gate so it meets the current fencing standard. No more than 4" between vertical members. No more than 2" from bottom of gates to ground. Put boards where fence meets building so there are no more than 4" between fence and buildin.
4.0
General Comments
pump PE A50 1266 Sta rite, 2hp, Pool certified VGB by wise engineering