Fence has less than 45' between horizontal members. Fence constructed prior to 2010-recommend repairing.
4.0
17.
The skimmer box/lid on pool deck b/t 5' and 8'3" section by building is starting to offset. Cannot have any offset >1/2". Monitor and repair in the off season.
Weir missing from one of the skimmers. Operator has ordered piece to replace.
4.0
16.
Fence has areas where there is >4' between vertical members, >2' between the ground the bottom of fence, less than 45' between horizontal members. Pool constructed prior to 2010 so it is recommended to repair.
Fence has areas where there is >4' between vertical members, >2' between the ground the bottom of fence, less than 45' between horizontal members. Pool constructed prior to 2010 so it is recommended to repair.
4.0
General Comments
Chemical storage room has been constructed with lights and mechanical ventilation.
Seasonal Permit Issued
The only operational gate is the gate from the parking lot-all other gates and doors are locked.
Fence has areas where there is >4" between vertical members, >2" between the ground the bottom of fence, less than 45" between horizontal members. Pool constructed prior to 2010 so it is recommended to repair.
4.0
19.
Must have a sign in 1-inch minimum letters stating, "ADULTS SHOULD NOT SWIM ALONE" and "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION". Repair sign that is incorrect in height of letters.
4.0
25.
Pool use to have a shed that had power and locked that was used as the chemical storage room. Shed is no longer on property. Must have a chemical storage room with lights and ventilation. It must be a room that has a door that can be locked and completely prevent access. Switch to ventilation fan must be restricted so it stays on at all times.
2.0
General Comments
Permit not issued. Call when items repaired for reinspection.
Floats on the safety rope were pushed to the side-should be located all along the rope no more then 5' apart.
2.0
17.
The skimmer lid and top on pool deck by the mens restroom is sticking up from the concrete 3/8 of an inch- monitor as you cannot have anymore then 1/2" protrusion-will need to be repaired if 1/2" or greater gap.
0.0
General Comments
Item that resulted in the intent has been corrected. Records for the last 30 days were available in the pump room. Intent to Suspend lifted.
Pump room mechanical ventilation is not operating. Repair the mechanical ventilation in the pump room as soon as possible.
2.0
General Comments
8. One weir was missing and was replaced at inspection. 16. Monitor gate to make sure it always self closes/self latches from all distances of opening and does not stick on grass. May need an additional spring or adjustment of current spring.
Where 2 units of fence join in corner at the back far right side is damaged and allowing for a gap of 4 1/2 inches. There cannot be any more then 4 inches between the vertical members on a fence.
4.0
24.
Flow meter is not operating- not indicating rate of flow. Repair.
4.0
General Comments
The intent to suspend that was issued on 7-25-17 remains in place due to the above issues mentioned on intent not repaired. Repair by Monday, August 28th in order to remain in operation.
Pool walls and floor have a black/green growth on them. All areas must be cleaned to remove all visible growth/algae.
4.0
10.
The safety rope was completely removed from break point-replace.
2.0
15.
Rope on the ring buoy was tangled and knotted up making it not usable in case of emergency-rope was un-knotted. CDI
6.0
16.
Fence on the far side back right corner is damaged allowing for a gap of 4 1/2 inches. Repair and secure 2 corners so no more then a 4 inch gap. Gate not at all closing or able to latch-repair.
4.0
17.
Lounge chairs on corners and shallow end not allowing for the required 6 feet of clean walkway - CDI.
4.0
24.
Flow meter is not operating- not indicating rate of flow. Repair.
A few tiles are missing from entrance to one skimmer-replace. The plaster on the pool wall and floor is pitting, chipping and in bad repair. By the 2017 operating season, the pool must be replastered.
4.0
12.
Chlorine tabs are in the skimmer baskets. Do not place chemicals in skimmer baskets.
The free chlorine level in pool water was not measurable, less than 0.5ppm. The free chlorine levels must be kept at a minimum of 1ppm.
6.0
3.
The pH of pool water was >8.0. The pH must be kept in a range of 7.2-7.8.
6.0
5.
The Pool Operator must provide daily written records of pH, free chlorine and main drain checks. There must also be weekly recordings of total alkalinity and cyanuric acid levels. As of July 29th, 2016 the pool operator gave written notice to Health Dept. of resignation. Therefor there are no written pool chemistry and maintenance records. Must provide a trained pool operator by August 29th, 2016.
4.0
7.
Pool wall and floor, stairs have black algae on them. Immediate measures need to be taken to clean and prevent. [
4.0
8.
Surface skimmers are missing weirs-replace.
4.0
10.
Floats on safety rope are not properly spaced. Arrange so there is not more than 5 feet of space between them.
2.0
11.
Caps for the bottom of ladder are on pool floor. Reattach all caps to the bottom of ladder.
2.0
24.
The pool was open and the circulation system was not operating. While the pool is open for the season, the circulation system must be on and properly operating to provide the proper disinfecting chemical strength, regulate pH and filter the water. Flow meter- rate of flow indicator was stuck in tube reading a gpm flow even though there is absolutely no flow of water in the system.
4.0
General Comments
*Pool permit is immediately suspended due to the inability to maintain the required free chlorine levels and pH range. Pool cannot be used to swim in by anyone at this time.
*An intent to suspend was issued on 7-20-2016 for violations #7, #8, #24 which is still in effect and must be repaired by 8-20-16.
*An intent to suspend is issued effective 7-29-16 due to the resignation of the pool operator. This must be corrected by 8-29-16.
The free chlorine level was less than 1 ppm at start of inspection. Chlorine added to the pool and now measuring at 1 ppm. Must maintain a minimum of 1ppm at all times of operation.
6.0
General Comments
Keep daily written records of free chlorine and pH Keep weekly records of total alkalinity and cyanuric acid Keep daily written records of main drain checks.
Water is too cloudy to see the main drains clearly, even with the scope. Must be able to clearly see main drains.
6.0
2.
The free chlorine in pool was 0ppm. Erosion feeder was empty and chlorine tabs were in pool. Cannot put chlorine tabs in pool or skimmer basket. Make sure erosion feeder is stocked. Must have a minimum of 1ppm free chlorine.
6.0
7.
Pool bottom is dirty w/debris. Clean to remove all debris.
4.0
8.
Two skimmers are missing weirs, replace.
4.0
11.
Ladder is missing end caps-replace.
2.0
12.
Vacuum line was open and uncapped on pool wall. When not in use to vacuum, cap.
4.0
15.
Ring buoy is in bad repair-replace.
6.0
24.
Flow meter is not operating-repair.
4.0
25.
Move the chemicals to the chemical storage room - store bags of chemicals above the ground.
2.0
General Comments
$25 reinspection fee paid in office b/f a reinspection can be done.
*The only approved points of entry to pool deck are the restroom exit doors and the gate by roadway/parking lot. *Light and fan are on the same switch in pump room-switch was taped on and must stay on.
*Main drains are secure and in good repair.
Keep daily pH levels, chlorine levels and main drain checks - written records. Keep weekly cyanuric acid levels and total alkalinity levels.
Equalizer lines have been plugged in skimmer. Must provide the approved VGB compliant covers by 2011 operating season.
4.0
General Comments
Compliance with the VGB act received and approved by Wayne Dushield, PE. Pump: pentair EQ 500 5 HP There must be a miniumn of 10 foot candles of light on pool deck when oper. past dusk, and all parts of pool visible. Keep daily chlorine and Ph records, Keep weekly cyanuric acid and total alkalinity levels. Keep daily checks on main drains by CPO.