PH was greater than 8.0 at start of inspection. CPO was able to lower pH at inspection. Maintain between 7.2-7.8
6.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
2.0
General Comments
8. Replace all missing weirs. 9. Monitor no divingmarkers for fading of drawn in extensions added to tiles. Once faded these need to be redrawn. Recommend modifying with a more permanent ink/paint to prevent fading.
"NO diving" markers on back side of pool are less than 4" in letter height. markers adjusted to 4" at inspection.
4.0
16.
gate opens from both directions. wooden stopper added on pool side of gate to prevent gate opening towards pool. gate must self close and self latch from fully opening and from opening 4" gate must also allow for no greater than 2" below gate. gate adjusted in height and tension to self close and self latch and maintain 2" gap.
4.0
18.
"warning no life guard on duty" sign has letters less than 4". sign modified to 4" letter height at inspection.
4.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
weirs missing in one skimmer. skimmer basket broken in one skimmer. replace missing weirs and broken baskets. In compliance for .2537 regulations.
4.0
9.
"No Diving" marker on the side at the 3' section where letter height is less than 4". Repair within 30 days of the date of this inspection.
4.0
16.
gate was not self closing self latching at start of inspection. Gate is dragging on cement preventing self closure. gate must be repaired to self close self latch with <2 under gate within 30 days of inspection.
4.0
17.
maintain 6' of open deck spacing. move furniture to maintain 6' deck clearance.
4.0
18.
"warning no lifeguard on duty" sign less than 4" in letter height. replace sign or modify to 4" letter height within 30 days.
4.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
weirs missing in one skimmer. skimmer basket broken in one skimmer. replace missing weirs and broken baskets. In compliance for .2537 regulations.
4.0
9.
"No Diving" marker on the side at the 3' section where letter height is less than 4". Letters modified at inspection to 4" in height. monitor throughout the season.
4.0
16.
gate was not self closing self latching at start of inspection. board members installed self closing device and repaired gate to self close/self latch at inspection. gap under one side greater than 2". modified to less than 2" at inspection.
4.0
17.
maintain 6' of open deck spacing. Furniture moved at inspection.
4.0
18.
"warning no lifeguard on duty" sign less than 4" in letter height. modified to 4" at inspection.
4.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
pool ladder is loose. tighten pool ladder and maintain in good repair.
2.0
16.
new gate was installed over concrete slab. one side of the gate over ground was greater than 2". concrete block placed under the end of the gate to reduce opening to less than 2".
4.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
Swimming pool should have a minimum of 4 inlets, only 2 plumbed. Fitting for the vacuum port to cover/close was missing-located on pool deck and installed. CDI
4.0
16.
Gate latch mechanism is not operational so entrance gate is not latching after opening- repair or replace the latch so gate is self closing and self latching. Intent Issued to repair.
4.0
29.
Only 1 toilet and hand sink available to bathers-should have a minimum of 1 restroom w/ toilet & hand sink for males as well as 1 toilet and 1 hand sink for females.
Pool should have a minimum of 4 returns-only has 2. Add eyeball fittings to returns to adjust flow.
4.0
29.
Should have 1 more set of restroom facilities (lavatory and toilet).
2.0
General Comments
No Night Swimming issuance of a permit by this department does not closure required by Executive Order 120 or subsequent orders in effect unless such orders are rescinded or superseded by another applicable order.
The pool floor is pitting and uneven, finish on stairs is very pitted. This is causing debris to be able to build up. The grout between wall tiles is missing allowing a dark growth to form. The pool floors and stairs will need to be refinished and grout repaired by next season.
4.0
10.
The safety rope in pool is only 1/4", should be 3/4" thick. Replace.
2.0
11.
Handrail on steps is loose and can be pulled up -repair.
2.0
12.
Pool should have a minimum of 4 returns-only has 2.
4.0
17.
Deck is separating from the concrete around pool and causing a trip hazard- There cannot be any offsets at or greater then 1/2" - repair by 2020 season.
4.0
25.
Equipment room should be kept locked.
2.0
29.
Should have 1 more set of restroom facilities (lavatory and toilet).
2.0
General Comments
Pool is only open for 6 more days so an Intent is not issued. Monitor coating on depth markers- must be skid resistant.
Chlorine was low at beginning of inspection. CPO added chlorine to get above 1ppm.
6.0
10.
Must have safety rope with buoys at shallow break point. Use 3/4" rope.
2.0
22.
Phone is not working. Phone rang back once but we could not communicate with 911. I called non emergency line from my cell phone and operator could said she could barely hear me on the pool phone.
6.0
24.
Make sure flow meter is operational and working at all times.
Several of the depth markers are a tile that is slippery- Depth markers on pool deck shall be a slip resistant surface. No-skid grip covering to make non-slippery.
4.0
10.
Floats on safety rope cannot be spaced anymore then 5 feet apart.
2.0
12.
Pool should have a minimum of 4 inlets.
4.0
16.
Gate should not have the ability to swing in -even slightly.
4.0
25.
Chemicals should be stored in the separate locked storage room.
2.0
29.
At a minimum, pool should have 2 restrooms (female w/ 1 toilet and sink) & (male w/ 1 toilet and sink).
All safety equipment and signage in place. Emergency phone works. Main drains secured. Throw rope had to be cut to one and one half the width of the pool. Rope was too long. Permit issued.
Out building used for storing chemicals does not have cross ventilation. Store chemicals in pump room until cross ventilation is installed in the out building.