Location: 1780 OUTLET CENTER DR. SELMA, NC 27576 Facility Type: Year-Round Swimming Pools Inspection Date: 05/25/2022
Score: 4
#
Comments
Points
25.
Chemicals should have a separate storage room from the equipment room.
2.0
29.
Pool should have a shower and restrooms at the pool deck since it is over 300 feet to the guest rooms.
2.0
General Comments
Flow ~85GPM
*Pool heater not operational *Lifeguard sign on fence is compliant, sign on building is not compliant *911 call center has old address of 1780 Industrial Park Dr-have changed to 1780 Outlet Center Dr. ] *Keel daily records of pH, free chlorine, and main drains. Keep weekly checks of total alkalinity, cyanuric acid levels.
Location: 1780 OUTLET CENTER DR. SELMA, NC 27576 Facility Type: Year-Round Swimming Pools Inspection Date: 08/16/2018
Score: 4
#
Comments
Points
5.
Pool records for water quality are being checked, however weekly records for total alkalinity and cyanuric acid levels are incomplete. Also place a check mark on sheet indicating main drain is secure. Check total alkalinity and cyanuric acid levels today and then do weekly from here on out to closing date. CDI
Location: 1780 OUTLET CENTER DR. SELMA, NC 27576 Facility Type: Year-Round Swimming Pools Inspection Date: 06/08/2017
Score: 16
#
Comments
Points
8.
One weir loose and one weir was missing. Corrected during the inspection.
4.0
11.
End cap missing from the bottom of the ladder. Corrected during the inspection.
2.0
15.
Rope on the ring buoy was 42 ft. 4 inches. Must be 1 1/2 times the width of the pool or 30 ft. Corrected during the inspection.
6.0
16.
One vertical member in the fence was bent with a gap of greater than 4 1/2 inches. The maximum gap must be 4 inches or less. Corrected during the inspection.
4.0
General Comments
Main drains secure. All safety in place. Emergency telephone works. Permit issued. Info on Electrical System Safety at Public Swimming Pools left with management.
Location: 1780 OUTLET CENTER DR. SELMA, NC 27576 Facility Type: Year-Round Swimming Pools Inspection Date: 06/10/2016
Score: 20
#
Comments
Points
3.
Pool Water pH was 7.0. Pool pH shall be 7.2-7.8. CDI pH brought to 7.2
6.0
15.
Ring buoy rope was 35ft. Throw rope shall be 1 1/2 the width of the pool. CDI throw rope was cut to 30 feet.
6.0
17.
Chairs were 5 feet from pool. Outside pools less than 1600 sq ft shall be 6 feet of clearance. CDI chairs moved.
4.0
25.
Chemicals stored in pump room. chemicals shall be stored in a separate ventilated storage room.
2.0
28.
Should have restrooms and showers within 300ft of bather entrance.
2.0
General Comments
5. Daily written records shall be kept for 6 months and record: Chlorine, pH, temperature, maid drain, and weekly alkalinity. 9. Depth markers beginning to fade. 16. Fence has some bends but less than 4 inches