Vacuum port was open and held open with a rock. Rock removed and port now self closing and closed.
4.0
16.
Side gate was unlocked. It does not meet compliance with .2528 (a) and must be kept locked. Fence has areas that there is over 2" between ground and bottom of fence, less than 45" between horizontal members. Due to date of construction, recommend repairing.
4.0
29.
Hot water in the restrooms was >110F. Should not be any warmer than 110F
Fence does not comply with .2528 (a). There are areas where the fence is less than 48" in height, more then 2" below fence and ground. Fence was constructed in 2006, and only should comply with .2528 (a). Fence also has less then 45" between horizontal members. Should have at least 45" between horizontal members.
4.0
29.
Hot water in the restrooms was >110F. Should not be any warmer than 110F.
2.0
General Comments
Service gate must remain locked due to not being compliant with rules.
Fence does not comply with .2528 (a). There are areas where the fence is less than 48" in height, more then 2" below fence and ground. Fence was constructed in 2006, and only should comply with .2528 (a). Fence also has less then 45" between horizontal members. Should have at least 45" between horizontal members.
4.0
29.
Hot water in the restrooms was >110F. Should not be any warmer than 110F.
2.0
General Comments
Seasonal permit issued Service gate must remain locked due to not being compliant with code.
Screws missing from a set of main drains. Operator was able to replace the missing screws. Main Drains is now secure. Monitor all main drains during the season.
6.0
16.
Fence does not comply with .2528. It is less then 48" in height. Fence should comply with .2528,, due to the date of construction it is not required.
4.0
29.
Hot water in the restroom is >120F. Should not be any warmer then 110F>
Fence is not compliant with the current section . 2528 (a). Due to pool fence being constructed prior to 2010 it is only recommended to comply. Should not have anymore then 2" between bottom of fence and ground, should have 45" between horizontal members.
4.0
25.
Doors to the chemical storage room was open and unoccupied at the start of inspection. This door must be kept closed and locked. Door closed and locked.
2.0
General Comments
Keep main drains on pool wall clean and debris free so they can be monitored and checked for repair.
The plaster top coat on many areas of pool was worn away exposing the base and concrete below. There are many cracks and pits in pool plaster. This pool must be resurfaced by next operating season. Replace missing tile in 1' deep section.
4.0
12.
Vacuum cover missing on the in-pool vacuum line outlet. Operator plugged. CDI
4.0
16.
Gate marked as 'Exit' gate is not compliant with .2528 (a) (3) (7). The release mechanism must be a minimum of 54" above the ground. There must be a minimum of 45" between horizontal members. Do not use unapproved gate until repaired.
4.0
17.
Areas on deck between coping and deck are separating-will need to be repaired so there is no offset.
0.0
24.
Two flow meters are not operating at start of inspection-operator repaired. CDI
4.0
29.
Hot water in the restroom was ~112F. Should not be any warmer then 110F.
One weir was missing on skimmer. Replaced during inspection. CDI Several skimmers were full of debris. Cleaned during inspection. CDI
4.0
16.
Some spots of fence was less than 48 inches because dirt had washed in and built those spots up. Those sections were dug out during inspection. CDI Bottom of fence in one spot was greater than 4 inches to grade. That spot was filled in to close the gap. CDI
4.0
General Comments
One depth marking at lazy river loose. Secure marker better. Permit issued.
Chlorine level was less than 1.0ppm at start of inspection. CPO was able to raise Chlorine level to 10 ppm by end of inspection by adding liquid chlorine to pool manually. Back up Chlorinator will be utilized while liquid chlorine feed system is repaired.
6.0
10.
Replace broken floats on safety rope at shallow end.
2.0
General Comments
1. Pool is slightly cloudy but all main drains are clearly visible from deck per rule. 5. Maintain daily written records when pool chemistry drops below levels required self close pool and make notes in records of remedy. 8. Some floating debris. Lifeguards were actively skimming pool surface. 7. Debris on bottom of pool in the lazy river. Lifeguards were actively cleaning this area.
One drain cover was damaged. Cover was replaced, but old frame was used. Frame expires at end of this season. See diagram on back of application for drawing. CDI
6.0
7.
3 Beauty tiles were missing below coping. Tiles were replaced. CDI
4.0
15.
One ring buoy rope was too short. Remove this from deck. If ring buoys are used on deck, they must be compliant. At all times pool is open, there must be 2 units of lifesaving equipment. (2 body hooks, AND 2 lifeguards or ring buoys with ropes.
4 screws were missing from main drains in the pool. Management was notified and replaced all screws during the inspections.
6.0
16.
Fencing was measured from the outside and was found to be less than 48" tall in various places. Management was notified and brought fence height into compliance during the inspection.
4.0
General Comments
Slide structure / stairway has areas where paint is starting to flake. Monitor and paint as the structure needs to avoid imminent hazardous in the future. All demerits from the last inspection are now in compliance with 15A NCAC 18A.25CC. Permit is being issued. No night swimming allowed.
2 main drains were observed during the inspection with a missing screw. Management was notified and screws were replaced. (Slide and lazy river drains) An outlet was found below a skimmer in 1' water without a cover. Management was notified and plugged the hole.
6.0
8.
1 skimmer was found in the pool without a weir. Management was notified and replaced the missing weir with a new one.
4.0
9.
3 tiles in the slide and lazy river area were found unattached to the surface. Management was notified and attached the tiles back to the proper areas.
4.0
16.
Fencing was measured from the outside and was found to be less than 48" tall in areas. Management will ask for re-inspection when work is completed.
Concrete slope on edge of blue pool in shallow area, has a spot that will need to be repaired by next operating season. It is just now starting to wear.
0.0
22.
Sign by Emergency telephone stating the dialing instructions and location of pool was not posted. CDI. Original sign broke off and was located for replacement during inspection.
6.0
General Comments
Intent to suspend lifted. All violations from 7/17/17 have been repaired.
Two sets of main drains has a screw missing each. Employee was able to reinstall the missing screws. Monitor to make sure all stay in the proper placement and secure.
6.0
7.
In several locations, the pool floor is pitting in round spots. Concrete outside the blue slide landing area is chipped. Walls in the lazy river have a black growth on them. Pool walls and floors must be cleaned to remove black growth by 8-17-17. Pool floor will need to be repaired in damaged areas by next operating season.
4.0
8.
4 skimmers are missing weirs. Replace by 8-17-17.
4.0
25.
Doors to the equipment rooms are being propped open due to heat from motors. Suggest installing additional exhaust fans and/or natural cross ventilation. Doors should be kept shut and locked.
No violations noted. Required signage and safety equipment in place. Emergency telephone works. Information on Electrical System Safety at Public Swimming Pools was left with the operator. Permit issued.
No demerits. Rescue tubes that are worn need to be replaced. Lifequards are used at poo. A gate attendant must be present at all times of the operating hours. Pool is open from dawn to dusk. Keep tape on power breaker # 8, 10, 12, 14, 16, to keep under water lights permentally turned off.
Couple spots in pool floors are cracking. Repair by next season.
0.0
8.
One weir was stuck. Was repaired by end of inspection and working properly.
4.0
16.
By next pool season, fence around block supports must made so they are not able to be climbed. Must have at least 30" between foot holds or vertical members less than 1 3/4" apart.
0.0
24.
flow meter was stuck at beginning of inspection. Was repaired by end of inspection.
4.0
General Comments
pump: (2) 7.5hp circulations, (4) 15hp lazy river, (1) 15hp slide, (1) 15 hp play pad pool certified VGB by Gorrell Allen Thompson PE, Life guard and gate attendant must be on duty at all times.