Fence has areas over 4' between vertical members, over 2' between ground and bottom of fence and not compliant with .2528 (a). Fence constructed prior to 2010, recommend compliance
Screws on the body hook are short and do not extend all the way through to secure on the opposite side of pole. Replace screws with longer ones and secure body hook to the pole. Repair.
6.0
16.
Gate must be compliant with .2528 (a)-There is less then 45" between vertical members and over 2" between the ground and bottom of gate. Install lattice that has an opening no greater than 1.75 inches wide between the diamonds. (picture drawn) Mount on outside of gate. Fence has areas over 4' between vertical members, over 2' between ground and bottom of fence and not compliant with .2528 (a). Fence constructed prior to 2010, recommend compliance
4.0
29.
Provide soap, paper towels in restroom
2.0
31.
Repair leak at the drain from the handsink
2.0
General Comments
Repair and call for a reinspection. Pool not open to bathers.
Fence has areas over 4" between vertical members, over 2" between ground and bottom of fence and not compliant with .2528 (a). Fence constructed prior to 2010, recommend compliance.
4.0
General Comments
Items resulting in Immediate Suspension have been corrected-Pool can open to bathers. Monitor.
Color band on steps is wearing in spots-monitor and repair by next season.
The free chlorine level in the pool at start of inspection was not measurable, less than a 1ppm. Operator had employee add chlorine to pool. Free chlorine level is now 2ppm. Must have a minimum of 1ppm at times of operation.
6.0
3.
The pH of pool water was 7.0. The pH must be between a 7.2-7.8 at times of operation. Adjust the pH to be in this range.
6.0
16.
Fence has areas >4" between the vertical members and >2" between the ground and bottom of fence. Fence was constructed prior to 2010-recommend conforming to .2528 (a).
4.0
23.
Chlorine tabs in skimmer basket. Chemicals shall not be placed in the basket and must only use automatic feeder - removed. CDI
4.0
24.
Flow meter is not operating as the bobber is stuck at bottom. Must be able to indicate rate of flow-operator repaired. CDI.
4.0
29.
Restroom did not have soap, paper towels or toilet paper and needs to be cleaned.
2.0
General Comments
Pool closed until the pH can be repaired and reinspected. Immediate Suspension issued.
Fence has areas not compliant w/ .2528 (a). Constructed prior to 2010.
4.0
General Comments
Equalizer lines are plugged on pool wall but not plugged in skimmer. This allows for debris to build up in the line. By next season the equalizer line must also be plugged in skimmer pot. Water level must be dropped down and removed from area between skimmer pot and pool wall - then plug.
-Keep daily records of pH, free chlorine and main drain checks
-Keep weekly records of total alkalinity and cyanuric acid levels.
Fence post on corner going to the chemical storage had been hit. Repair man fixed post so there was no more than 4" space between vertical post and no less than 45" space between horizontal members. CDI
The turtle used to close off the equalizer line was above the basket in skimmer. CPO fixed the turtle. The weir was also installed backwards. The weir must be installed so it drops inside the skimmer. It would not go down into the skimmer.
4.0
15.
Rope to ring buoy was 25' long, must be 30' long.
6.0
16.
The gate has more than 2" gap from ground to the bottom of gate. Add a sweep or move lattice down so there is no more than a 2" gap.
4.0
22.
The emergency phone was not working owner replaced with a new phone that did call out to 911.
6.0
24.
Flow meter is stuck needs to be free flowing. The motor to the pump has been replaced recently and must be inspected by building inspection.
16. Pool fence was build in 2008 is 51.5" tall with 46"between horizontal members, 3.5"between vertical members and 3" under bottom. Gate is in compliance to current code. Fencing meets pre 2010 code. No Night Swimming.
Ring buoy was missing the outer rope and had a tear in the cover. This ring buoy is not approved and a new one must be provided. Replace and provide a rope attached that is 1 1/2 times width of pool.
6.0
16.
Back corner of fence is damaged and gap over 4 inches is currently there. Repair the damaged fence so it is secure and not gaps over 4".
4.0
17.
The area between the coping and pool deck on the backside of pool is over 1/2". Seal in area so coping slopes to pool deck or raise pool deck- do not cover the depth markers and no diving tile.
Pool wall has a missing tile beside step ladder. Needs to be replaced.
4.0
15.
Ring buoy was in bad repair. CDI New ring buoy put in its place. Throw rope shall be 1 1/2 the width of pool. 30ft
6.0
17.
Chairs less than 6 feet from pool. CDI chairs moved.
4.0
25.
Chemicals should be stored in chemical storage room and not in pump room.
2.0
28.
Bathroom always needs to be supplied with soap.
2.0
General Comments
5. Records should be taken everyday. One day missed. Also always check main drain & weekly alkalinity. 7. Pool floors have some chipping and needs to be fixed by next pool season. 13. Contrasting band on steps need to be refinished by next pool season. Fading
A sing stating: "Children should not use the swimming pool without adult supervision." and "Adults should not swim alone." is required in one inch lettering. Sign was posted during inspection.
4.0
General Comments
General Comments: 5. Daily records needs to have main drain checks. 13. contrasting color band may need to be repainted during pool season.
Pool bottom has a number of areas with chipped paint. Make sure these areas are kept clean. pool bottom needs to be repaired and painted before the next permitting season.
4.0
General Comments
Pool was clear and main drains were secured. Daily pool records are now being maintained.
Pool showed no chlorine when tested. Chlorine was boosted to 1.0 ppm, which is the minimum.
6.0
5.
No pool records written down since 5/20/15. Daily records must be written down for each day the pool is operating. Need to record chlorine levels, pH, and a daily check for secure drain covers.
4.0
General Comments
Pool is somewhat cloudy and the drain covers can barely be seen. Management has voluntarily closed the pool until the water clears. Pool closed sign was put up before the end of the inspection.
Phone line went to 911 center. The address given from 911 was 117 South Equity Drive, not 170. Call telephone company to get the correct address changed.
Steps entering into the pool had some algea on them , employee cleaned during inspection.
4.0
17.
Table and chairs was inside the 6' walking area of pool deck. Employees moved the table and chairs. Keep all pool furniture 6' away from the edge of the pool
4.0
22.
The telephone number was faded at the emergency phone. It also did not match the 911 number that was given. Keep all information visible and matching with 911.
6.0
General Comments
18/19. The pool rule sign will need to be replaced soon. Pool is open from dawn to dusk. Permit is being issued.
Equalizer lines have been capped on the inside of skimmer even though covers have been installed on pool wall and approved by Wise Engineering. Should remove caps from inside skimmer-must be done by 2011 operating season. Do not remove the VGB approved covers from equalizers on wall of pool.
4.0
General Comments
-Compliance with VGB received from Wise Engineering in form of official letter. -1 HP pump installed -If night swimming is allowed then there must be 10fc of light on pool deck. Call if going to stay open past 8:00pm (as listed on application). 989-5180
Inspection by John Phillips earlier in day approved all other items other then the 6pt & VGB.