fence height is less than 48" and is not in compliance for current code. fence is compliant to applicable code of date of construction. recommend replacing/repairing fence to meet current code. Gate is compliant to current code.
4.0
25.
pump room forced ventilation is not operable. repair forced ventilation fan.
2.0
29.
Hot water in excess of 110F in restrooms. Hot water should be 110F or less.
fence height is less than 48" and is not in compliance for current code. fence is compliant to applicable code of date of construction. recommend replacing/repairing fence to meet current code. Gate is compliant to current code.
4.0
25.
pump room forced ventilation is not operable. repair forced ventilation fan. Chemical room has cross draft ventilation.
2.0
29.
Hot water in excess of 110F in restrooms. Hot water should be 110F or less.
replace the bumper on the pool ladder foot that is missing.
2.0
15.
ring buoy rope at 29 feet and should be at 27 feet. Operator retied to correct length.
6.0
16.
The fence is less than 48" by the parking lot due to landscaping. Fence is in compliance for the code enforced for the year the fencing was constructed.
4.0
18.
Warning no life guard on duty sign had lettering less than 4 inches. Operator made a temporary sign with 4 inch lettering.
4.0
25.
Mechanical ventilation in the pump room is not operating. Natural cross draft or mechanical ventilation is required.
2.0
29.
Hot water in excess of 110F in restrooms. Hot water should be 110F or less.
pH of pool was less than 7.2. pool ph must remain between 7.2-7.8. CPO was able to raise ph to 7.4 at inspection.
6.0
11.
replace the bumper on the pool ladder foot that is missing.
2.0
16.
The fence is less than 48" by the parking lot due to landscaping. Fence is in compliance for the code enforced for the year the fencing was constructed.
4.0
25.
Mechanical ventilation in the pump room is not operating. Natural cross draft or mechanical ventilation is required.
2.0
29.
Hot water in excess of 110F in restrooms. Hot water should be 110F or less.
Replace the bumper on the ladder foot on the pool ladder that is missing. Maintain ladders in good repair.
2.0
15.
Body hook must be attached to a 12" non telescoping pole. Hook was attached to telescoping pole and was replaced by 12" non telescoping pole at inspection.
6.0
16.
The fence is less than 48" by the parking lot due to landscaping. Fencing is in compliance for the code enforced for the year the fencing was built.
4.0
25.
Mechanical ventilation in the pump room is not operating. Natural cross draft or mechanical ventilation is required.
2.0
29.
Ho water in excess of 110F in restrooms. Hot water should be 110F or less.
2.0
General Comments
One return cover is cracked and missing the directional insert. Maintain all inlets and fittings in good repair. Night swimming is permitted. Check lighting regularly to ensure all lights are working.
At start of inspection pH was at 7 pH. Should be at 7.2-7.8. CPO able to get pH up to 7.2.
6.0
6.
Both main drains missing screws. 1 had 2 out of the 4 screws. The 2nd had 1 out of 4 with the 2nd screw in it but you can see it is not screwed in. Both main drains need to be correctly screwed down.
6.0
16.
First time tested gate it did not self latch. CPO made adjustments and now self latching. Monitor to ensure it continues to self latch.
4.0
22.
Emergency phone not working. When picked up nothing happened.
Ph was below 7.0 when first checked. Employees added chemicals after waiting pH was still below 7.0. On the third try after a few hours wait the pH was at 7.2.
6.0
17.
Before next year pool season (2019) there are some areas that concrete is chipping.
Records for daily and weekly alk. are recorded don't forget about cyanuric acid readings.
0.0
7.
Piece of glass was seen on the bottom of pool floor. Manager had employee vacuum the pool during inspection.
4.0
24.
flow meter is stuck, must be free flowing. Chlorine tablets were in both skimmers. Tablets were removed during inspection. You have 30 days to repair flow meter.
Written records were reviewed. Daily records were kept however, weekly records of total alkalinity and cyanuric acid level were not kept documented. 15A NCAC 18A.2535 was reviewed with management and written documentation was made by myself in the record book to assist with the process.
4.0
16.
The gate was partially repaired in regards to the 2 inch requirement from grade level to the bottom of the gate. Management was notified and made aware of the 2 inch requirement had to extend across the entire gate bottom. The edges of the gate did not meet requirements. Management made necessary repairs during the inspection. Gate is now in compliance with 15A NCAC 18A.2528
4.0
29.
Hot water was 128F. Hot water should be no more than 110F.
Ring buoy was found to have an extensive amount of "wear and tear" Pool management was notified and order another ring buoy. Rope connected to the ring buoy was 6 inches to short. Another rope was ordered.
6.0
16.
The gate is greater than 2 inches from grade level to bottom of the gate. Management was notified and explained that the gate must be 2 inches or less from grade to the bottom of the fence. Once set of vertical members were 4 1/8 inches apart. Some areas around the outside fence were less than 48 inches from grade to top of fence. Management was notified of all fence and gate dimensions and 15A NCAC 18A.2528 (fences)
4.0
17.
Deck space was not adequate in several areas. Management was notified and corrected deck space.
Deck space must be 6 feet or more and 5 feet or more around diving boards, handrails, or other permanent structure installed on a swimming pool deck.
4.0
29.
Hot water was 128F. Hot water should be no more than 110F.
pH 6.8 when first checked. Corrected to 7.2. Keep pH in the range of 7.2 to 7.8.
6.0
17.
A couple of tables were 5 ft from the pool edge. 6 ft of clear deck space is required. Corrected during the inspection.
4.0
18.
Warning No Life Guard on Duty sign in 4 inch letters not posted in the pool area. Corrected during the inspection.
4.0
24.
Flow meter not operating properly. Corrected during the inspection.
4.0
29.
Hot water in the restrooms is 126 degrees F. Hot water cannot exceed 110 degrees F.
2.0
General Comments
Main drains secured. Safety equipment in place. Emergency telephone works. Permit issued. Information on Electrical System Safety at Public Swimming Pools left with operator.
The pH of pool water was a 7.0 at start of inspection. pH increaser was added and now a 7.6. Must stay between 7.2-7.6
6.0
7.
Tiles on the pool wall at 3 foot deep section have a crack in them. Pool is not loosing water and there is not any debris build up around it so the crack is on surface. Monitor, may need repairing if it cracks further.
4.0
22.
Emergency telephone was not calling 911 at start of inspection-Phone company repaired and now phone is capable of directly connecting to the 911 call center.
In the chemical room, motor to fan was not operational. Unit was removed from wall to allow a natural cross ventilation from slats in door to square opening in wall. Keep bags of chemicals stored above the ground.
One ring buoy rope was too short. Other buoy was OK. Only one is required, Pool put one with too short of a rope in storage unti until rope is replaced. Replace rusty screwe in body hook. Make sure flat side of screw/bolt is on inside so it does not injure the person if used.
6.0
16.
Gate was sticking on screw head and not closing properly from close distances. Repaired by end of inspection.
4.0
29.
Hot water in restrooms should not exceed 110 degrees.
Hot water in restrooms by pool entrance was 130*F. Must be a maximum of 110*F.
2.0
General Comments
Pump has just recently been replaced. Went from a 1.5hp to 1hp pump. Pool closes at 10:00pm, each night. Keep daily check on main drain covers and equalizer covers. Recommended replaceing cracked skimmer basket.
Equalizer line to skimmers have been plugged on pool wall. Must have VGB compliant covers by 2011 operating season.
4.0
17.
Must have 6 feet of clear walkway aroung pool on deck. Chairs and tables moved to allow the 6 feet.
4.0
29.
Hot water in restrooms by pool entrance from Hotel 130F. Must be a maximum of 110F.
2.0
General Comments
-Pump: Pentair Challenger 1 1/2 HP -Compliance with the VGB Act received and approved, letter from Randy Wise Engineering. -Pool closes at 10:00pm. Lights on pool deck must provide a minimum of 10 foot candles in pool enclosure. All parts of pool must be clearly visible. -Document weekly total alkalinity and cyanuric acid levels. Daily checks on main drains.
Gate is sticking and does not close and latch properly. Gates must be self
4.0
17.
Keep 6' of clear work space around pool.
4.0
22.
Door leading to emergency telephone was locked. This door must be kept unlocked at all times so emergency telephone is easily accessible in case of emergency. Door was unlocked!
6.0
29.
Water should not be hotter than 110 f in restrooms.