Weirs were missing in skimmers. Due to the age of the pool pool is in compliance. vacuuming port was missing cover that self closes self latches due to age of pool a cap was used.
4.0
13.
contrasting band on steps is greater than 1 inch from leading edge. Due to age of pool, pool is in compliance.
4.0
15.
Ring buoy rope was fraying. ring buoy must be in good repair. operator replaced with new buoy.
6.0
16.
gate had area under that was greater than 2 inches. Areas under gate must be less than 2 inches. operator fixed during inspection.
4.0
General Comments
911 operator could not identify the address from which the phone was called. Recommend getting fixed.
Inspection conducted by Kerry Taylor during training.
Ladders need end caps on bottom of rails. Ladder steps should be spaced so they are no more then 6" from pool wall. Handrail on steps was loose and must be secured. Operator secured-CDI
2.0
12.
Plug for vacuum was not in at start of inspection. operator was able to plug.
4.0
13.
Color band on steps is over 1" from edge of step. Should not be >1" away from leading edge.
4.0
24.
Flow meter was not operating at start of inspection.
4.0
General Comments
*On daily records, include a space to check off daily main drain secure and in good repair. *Remove the faded orange/red sign by phone w/incorrect dialing instructions-Correct instructions are on sign above phone box. *If on pool deck-gate on the left of building must be kept locked.
Floats on safety rope must be no more than 5 ft apart.
2.0
11.
Ladders need caps, so there are no hazards to swimmers and so walls don't get damaged farther. Should have no more than 6" between steps and walls. make sure ladders are tight.
2.0
General Comments
Intent lifted. Copy left in office drop box. Could not access pump and chemical room.
Floats on safety rope were all pushed together at one side of pool. Floats should be no more than 5' apart.
2.0
11.
Ladders need caps at bottom so they do not damage wall of pool any more! Also should not have more than 6" of space between steps and walls.
2.0
12.
Vacuum port is missing plug. Port must always have plug when not in use. Correct by 8/19/18 or permit will be suspended.
4.0
17.
Several spots on deck and coping of pool are chipped. Repair ASAP so there are no trip hazards. Must be repaired by 8/19/18 or permit will be suspended.
Floats on the safety rope were pushed together at the start of the inspection. Space evenly apart of rope but no more than 5' apart.
2.0
11.
Ladders need end caps on bottom of rails. Ladder should be spaced so they are no more then 6" from edge/pool wall. Currently over the 6" from pool wall.
2.0
12.
plug for vacuum was no in at start of inspection, exposing a potential safety hazard. CDI
4.0
22.
At start of the inspection, no emergency telephone was available. Operator purchased phone and installed. Phone connects to 911. CDI
6.0
24.
Flow meter was not operating, operator repaired. CDI
4.0
General Comments
Monitor ring buoy, it had a few rough spots, replace when it is worn.
Surface skimmers should have equalizers or there should be another water leveling system.
4.0
11.
Ladders are installed >7" away from pool wall. Should be installed so that the steps are between 3"-6" from pool wall.
2.0
12.
Vacuum plug missing from port on pool wall. When not in immediate use for vacuuming pool, port must be plugged.
4.0
15.
Ring buoy was in bad repair with several rips in cover. New buoy was provided. Monitor to make sure it stays in good repair.
6.0
General Comments
-Screws in wall inlet covers are rusty. Monitor to make sure they stay secure and in place during the season. -Replace the end cap on 1 ladder that is missing one.
Could not access pump room or equipment room! Chemistry is close to minimum standards. Maintain 7.2-7.8 pH and greater than 1ppm in times of heavey use or when heat of the day.
pH was at 8.0 at beginning of inspection. Was down to 7.8 by end of inspection after chemicals were added. Keep pH 7.2-7.8 at all times.
6.0
8.
Skimmmers should have equalizer lines to prevent pump damage if water level drops.
4.0
18.
Keep all warning signs posted."CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION and ADULTS SHOULD NOT SWIM ALONE must be in 4" letters.
4.0
24.
Flow meter was not operating at beginning of insepction. Was clogged.
Skimmer should have equalizers to protect pump if water level drops.
4.0
10.
Safety rope should be 3/4" instead of 1/2" rope.
2.0
16.
Fence mesh is 2 3/8". Fence cannot exceed 2 1/4 mesh. No gaps larger than 2" between bottom of fence and ground and at least 48" high. Latch must be 54" above grade. Fence must meet current rules by next season. Contact us prior to replacing.