Rope on the ring buoy was shorter then the required length. Rope must be 46.5" in length. Operator was able to replace the rope with one that is the correct length.
6.0
29.
Hot water in the restrooms was ~112F. Should not be any warmer then 110F. Adjust the heater down to provide a maximum water temp of 110F.
pH was above 7.8 at start of inspection. CPO was able to lower pH to correct range at inspection.
6.0
General Comments
weirs and flow meter have been approved from 30 day intent. Intent lifted. 23. hand feeding of granular chlorine is not an approved disinfection method. Chlorine must be delivered through an approved NSF standard chemical feed system.
Chlorine level was below 1.0ppm at start of inspection. Granular chlorine was added to pool and sticks added to erosion feeder at inspection raising chlorine to 3.0 ppm maintain at least 1.0 ppm of chlorine at all times pool is open.
6.0
8.
Multiple weirs missing in skimmers. Skimmers must be in good repair with weirs in place. 30 days to replace all missing weirs.
4.0
24.
Flow meter was stuck at inspection. Flow meter must be in good condition and functioning properly. 30 days to repair/replace.
4.0
General Comments
Yard hydrant and electrical boxes on the outside of fence may provide footholds over the fence. it is recommended to remove/move these items.
Pool water was very cloudy at start of inspection. Pool clarity improved over inspection where all maindrains were visible from the pool deck and screws in cover were visible. Maintain pool clarity at all times of operation.
6.0
8.
One missing weir was replaced at inspection. all skimmers must have weirs in place.
4.0
24.
flow meter was stuck and repaired during inspection. Flow meter must be functioning properly at all times.
4.0
General Comments
Yard hydrant and electrical boxes on the outside of fence may provide footholds over the fence. it is recommended to remove/move these items.
Due to the surface area square footage, there must be 8 feet of clear walkway around pool on deck. Chairs were obstructing the walkway. Operator moved chairs to provide 8 feet.
Weir missing on one skimmer. Corrected during the inspection.
4.0
24.
Flow meter stuck. Corrected during inspection.
4.0
General Comments
All signs and safety equipment in place. Emergency telephone works. Permit issued. Information on Electrical System Safety at Public Swimming Pools left with the operator.