Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 04/09/2024
Score: 6
#
Comments
Points
16.
There was greater then 2" between the bottom of the gate and the ground. Cannot have anymore then 2". Operator was able to install a barrier at the bottom of the gate to fill the gap. Monitor. CDI
4.0
25.
Large container of liquid chlorine in the pump room. Should be stored in a chemical storage room.
2.0
General Comments
Faded 'WARNING NO LIFEGUARD ON DUTY' sign removed-new sign posted in the wading pool barrier.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 08/17/2023
Score: 6
#
Comments
Points
24.
flow meter is reading 140 gpm which exceeds the maximum capability of the pump. water is dripping from the top of the flow meter. replace flow meter. a rate of flow indicator shall be installed in a filtered water line located so that the rate of circulation is indicated. flow meter does not appear to be reading accurately. replace within 30 days of date of inspection.
4.0
25.
a separate chemical storage room is required large barrels of liquid chlorine stored in pump room.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 04/12/2023
Score: 10
#
Comments
Points
16.
All pool gates must self close and self latch. latch on gate detached so gate would not self latch. operator repaired locking mechanism at inspection allowing gate to correctly self close and self latch.
4.0
24.
a rate of flow indicator shall be installed on the filtered water line and located so that the rate of circulation is indicated. flow meter was stuck and unable to read flow. operator replaced the flow meter at inspection and flow was able to be verified.
4.0
25.
a separate chemical storage room is required large barrels of liquid chlorine stored in pump room.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 08/17/2021
Score: 16
#
Comments
Points
2.
The free chlorine level in the wading pool was less then a 1ppm. Granular added to skimmer, dissolved and allowed to circulate. It is now a 7.5ppm. Must be a minimum of 2ppm. CDI
6.0
3.
The pH of pool watr was greater then a 8. Muratic acid added, allowed to circulate. The pH is now a 7.8. Must be between 7.2-7.8. CDI
6.0
16.
Vertical members on fence are bent and there is over 4" between them. Pool fence was constructed prior to 2010 so it is only recommended to repair.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 05/20/2021
Score: 12
#
Comments
Points
2.
The free chlorine level of the wading pool was 1ppm at start of inspection. This is a wading pool which must keep a minimum of 2ppm free chlorine. Chlorine added and allowed to circulate, now 10ppm. CDI
6.0
3.
pH of pool water was 7.0 at start. The operator adjusted w/chemical and allowed to circulate. The pH is now a 7.2-must be between 7.2-7.8.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 05/12/2020
Score: 4
#
Comments
Points
17.
Picnic table obstructing required deck spacing. Table moved to allow unobstructed deck space. Table moved to allow unobstructed deck space.
4.0
25.
Fan in pump room not working when first checked. Operator worked on fan. Could not get fan to work properly. Will be back for reinspection om Thursday.
0.0
General Comments
No night swimming. Can not open until executive orders have been lifted. No permit issued.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 07/10/2019
Score: 18
#
Comments
Points
2.
Chlorine level was 0 ppm at start of inspection. Raised to 10 ppm by CPO at inspection.
6.0
3.
pH was reading greater than 8.0 at start of inspection. pH lowered to 7.2 by CPO at inspection.
6.0
17.
Pool furniture obstructing required deck spacing of 4'. Pool furniture was moved to allow unobstructed deck space.
4.0
25.
Liquid chlorine barrels stored in pump room. Chemicals should be stored separated from pump room. Fan in pump room was not on at start of inspection. pump room ventilation fan must operate at all times.
Location: 136 RIVER HILLS DRIVE CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 05/17/2017
Score: 4
#
Comments
Points
18.
Within the fence around the wading pool, there must be a sign in 4 inch letters stating "WARNING NO LIFEGUARD ON DUTY". Pool operator moved sign within fence.