Location: 512 RIDGECREST DR. CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 08/01/2024
Score: 10
#
Comments
Points
2.
The free chlorine level of wading pool at the start was not measurable. Operator filled chlorinator and allowed to circulate. It is now a 2ppm. Must be a minimum of 2.0ppm at all times.
6.0
16.
Mesh on fence is over 2.25'. Mesh should be no larger than 2.25'. Gate swings out away from the wading pool-should swing into the wading pool deck. Fence constructed prior to 1991-recommend repairing.
Location: 512 RIDGECREST DR. CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 05/24/2024
Score: 4
#
Comments
Points
16.
Mesh on fence is over 2.25". Mesh should be no larger than 2.25". Gate swings out away from the wading pool-should swing into the wading pool deck. Fence constructed prior to 1991-recommend repairing.
Location: 512 RIDGECREST DR. CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 07/30/2019
Score: 12
#
Comments
Points
2.
At the start of inspection the free chlorine level was ~1ppm. A wading pool must have a minimum of 2ppm free chlorine. Chlorine adjusted and now providing 10ppm. Monitor to make sure it stays at 2ppm minimum. CDI
6.0
5.
Check and record weekly cyanuric acid levels and total alkalinity
0.0
16.
Parts of the chainlink fence are 2.5 inches wide when measured on the square. Should not be any wider then 2.25 inches.
4.0
25.
Chemicals should be stored in a separate locked storage room away from the pump room.
2.0
General Comments
#16 and #25 should be repaired but due to date of construction of pool (before 1991) they are not mandated.
Location: 512 RIDGECREST DR. CLAYTON, NC 27520 Facility Type: Seasonal Wading Pool Inspection Date: 05/21/2018
Score: 10
#
Comments
Points
16.
Gate to wading pool had more than 2" in a few spots on bottom and was 47 3/4" at top fence post that goes horizontally. PVC pipe was added to top and bottom to fix clearance issues. CDI Couple spots in fence are below 48".
4.0
22.
Phone did not dial 911 at beginning of inspection. Phone was replaced and is working properly. CDI Phone was replaced and is working properly. CDI