Step ladder was damaged. operator was able to fix during inspection
2.0
16.
Horizontal members should be no more than 45" apart. Horizontal members are less than 45" apart with 4" between pickets. There should be no more than 2" under the bottom of the fence. There is more than 2" between the bottom of the fence and the ground but less than 4". Fence does not meet current fencing regulations but is in compliance for the year of the fence construction.
4.0
24.
Flow meter was not operating properly. Operator was able to fix during inspection.
water Chlorine was 0ppm. Free chlorine should be at least 1.0ppm. Operator adjusted chemicals and a reading of 5.0ppm was final.
6.0
16.
Horizontal members should be no more than 45" apart. Horizontal members are less than 45" apart with 4" between pickets. There should be no more than 2" under the bottom of the fence. There is more than 2" between the bottom of the fence and the ground but less than 4". Fence does not meet current fencing regulations but is in compliance for the year of the fence construction.
4.0
18.
"Children should not use the swimming pool without adult supervision" and "adults should not swim alone" warning statements were not 1" in letter height. Sign was modified at inspection to extend letters to the correct letter height of 1". These two statements in exact wording are required to be in 1" letters minimum.
4.0
General Comments
Water was cloudy at start of inspection due to vaccuuming before the inspection. Main drains and screws to the maindrains were visible from the pool deck at all times during the inspection. Maintain water clarity so that maindrains are visible from the pool deck at all times. If water becomes too cloudy close the pool until the issue is resolved.
At start of inspection chlorine was at 0ppm. CPO made adjustments and chlorine now at 3ppm.
6.0
15.
At start of inspection ring buoy had a hole in it were you could see the yellow inside. This is no longer in good repair. CPO went and got a new ring buoy that is in good repair.
6.0
24.
Flow meter was stuck. CPO repaired flow meter so working properly.
4.0
25.
Bags of chemicals being stored on the ground in chemical room. Keep all chemicals above the floor.
2.0
General Comments
* Not using outdoor restrooms but can use one right inside.
Depth markers around the pool were painted on and some did not meet the 4 inch min size requirement. Markings were painted over and made bigger during inspection. CDI
4.0
General Comments
Permit issued. Follow any applicable executive orders if required. No night swimming!
911 operator was unable to hear when called and phone was having trouble getting through. CPO cleaned phone receiver and hooked phone back up and 911 operator was able to hear caller and verify address. Phone was operating correctly at inspection.
6.0
General Comments
Bags of pool salt on the floor of chemical room. Store pool chemicals off the floor.
A couple of depth markers/letters for no diving were not 4" tall. Owner repainted numbers and letters as needed.
4.0
16.
The front gate (parking lot) was not latching/self closing from close distance. Owner repaired, now the gate self closes and latches from all distances.
One hand rail was loose. Tightened during the inspection.
2.0
15.
Body hook was missing one screw and bolt. Corrected during the inspection.
6.0
General Comments
All safety equipment and required signage in place. Emergency telephone works. Permit issued. Information sheet on Electrical System and Public Swimming Pools was left with management.
pool pH must maintain 7.2-7.8 at all times. Was high at beginning of inspection. Was brought down to 7.6 by end of inspection. CDI
6.0
15.
Ring buoy throw rope was wrapped around buoy so it was only about half the distance it needed to be. Rope was untangled and unwound off buoy. Rope must be 1.5 times the width of pool. CDI
6.0
22.
Get phone company to remove Apt B from 911 enhanced 911 and put pool.
0.0
General Comments
GC- Warning no life guard on duty sign is starting to fade. Replace if it becomes no longer readable.
Need a daily record of checking main drains on the pool record. Corrected during the inspection by adding a new column for drain check on the daily record.
4.0
General Comments
Keep check of outer rope on the US Coast Guard throw ring. rope is starting to fray, but is still intact. Replace if fraying continues.
Flow meter not attached to pump and salt system. Flow meter must be installed and operating properly. Install flow meter and call back for reinspection.