pH at 8. pH should be at 7.2-7.8. CPO adjusted to 7.4.
6.0
9.
depth markers must be 4" in letter height. "NO diving" must have 4" letter height. Markers have faded and were adjusted/extended to 4" at inspection. maintain throughout season.
4.0
16.
fence has greater than 2" under bottom of fence but less than 4" fence is compliant for year of construction.
depth markers must be 4" in letter height. "NO diving" must have 4" letter height. Markers have faded and were adjusted/extended to 4" at inspection. maintain throughout season.
4.0
11.
replace rubber bumpers on pool ladder feet. ladder feet should rest against pool wall.
2.0
16.
fence has greater than 2" under bottom of fence but less than 4" fence is compliant for year of construction.
depth markers must be 4" in letter height. "NO diving" must have 4" letter height. Markers have faded and were adjusted/extended to 4" at inspection. maintain throughout season.
4.0
11.
replace rubber bumpers on pool ladder feet. ladder feet should rest against pool wall.
2.0
15.
ring buoy rope has dry rotted and fraying. Rope was replaced at inspection. Monitor through season and replace if fraying. maintain at 27'.
6.0
16.
fence has greater than 2" under bottom of fence but less than 4" fence is compliant for year of construction.
4.0
General Comments
25. chemical room is using natural cross draft ventillation. recommend repairing/replacing forced ventilation.
Chlorine reading was less than 1.0ppm. maintain chlorine level at least at 1.0ppm. raised to 5.0ppm at inspection by CPO
6.0
3.
pH was greater than 8.0. pH must be maintained between 7.2-7.8. pH lowered to 7.6 at inspection by CPO
6.0
11.
ladder is loose and needs tightening. maintain ladders in good repair.
2.0
18.
warning sign with 2 required phrases has faded from being modified at opening inspection. letters must be 1"in height. older sign found in pump room with correct lettering was hung up at pool at inspection.
ph of pool was greater than 8.0. maintain pH between 7.2-7.8
6.0
9.
Depth markers must be at least 4" in height on the numerals. A few numerals were less than 4" and were extended to the correct size at inspection.
4.0
11.
Tighten pool ladder. pool ladder feet should rest against the wall. Maintain ladders in good repair.
2.0
18.
Warning signs with phrases " Adults should not swim alone" and " Children should not use the swimming pool without adult supervision" was not written in required 1" letters. letters were modified to at least 1" at inspection.
4.0
General Comments
Permit not issued due to pool pH. Call for reinspection after fee has been paid. flow meter reading 95 gpm at max of the pump curve flow.
The top of the latch for the gate is at 50 inches. Release mechanism of self latching device has to be 54 inches from bottom of the gate. If located less then 54 inches then shall require the use of key, combination, or card reader to open. CPO was able to move release mechanism up to 54 inches.
4.0
24.
Flow meter stuck. CPO was able to repair flow meter
4.0
29.
Hot water cannot exceed 110F in bathrooms.
2.0
General Comments
Night swimming approved Follow all current executive orders Permit issued
Depth markers must be 4" in height. stickers have been replaced. Some numerals are slightly shorter than 4". CPO was able to modify the depth markers to meet the 4" requirement. "NO DIVING" letters were also modified to meet the 4" requirement.
4.0
29.
Hot water cannot exceed 110F in bathrooms.
2.0
General Comments
Monitor flow meter to ensure it is functioning properly.
Depth markings shall be in arabic numerals at least 4" high. Most numerals indicating pool depth were not 4" in height. "No Diving" markers shall consist of the words "No Diving" in letters at least 4" high or at least a 6 x6" international symbol for no diving in red/black on a white background. International symbol stickers were not 6x6" stickers indicating "No Diving" were not in 4" lettering. Replace/modify 6x6 symbols/NO diving markers to ensure they are correct size. 30 days to repair.
4.0
18.
statements "children should not use the swimming pool without adult supervision" and "adults should not swim alone" in exact wording must be 1" in height. Current sign letters are less than 1" in height. Replace with correct signage within 30 days.
4.0
24.
Flow meter is stuck. Repair so flow meter is operating correctly and metal piece inside moves freely. 30 days to repair.
Daily records had no documented records for 5/19/18. The pool operator shall inspect and maintain the pool showing written documentation and records for the last 6 months. Maintain records and daily pool maintenance.
4.0
16.
Fence has 4 locations where vertical members are 4 1/8 inches apart. This pool was constructed prior to April 1,2010 therefore is exempted reference 15ANCAN18A.2528(c)
4.0
29.
Hot water temp was 128F. Hot water temp should be no more than 110F.
Fencing around the pool was less than 48 inches from grade to the top of the fence. Management was notified and removed landscaping store to gain the required height of 48 inches. The fence is now in compliance.
4.0
17.
Deck spacing was less than 6 feet from pool-edge of deck to furniture. Deck spacing on outdoor pools must be atleast 6 feet and 5ft behind all handrails and ladders. Management was notified and adjusted furniture to be in compliance.
4.0
21.
An underwater light was observed to be loose from the housing and full of water. Management was notified and removed the light and ordered a new one. Pool cannot operate until the light is repaired.
4.0
29.
Hot water was 140F. Hot water should be no more than 110F.
Rope on one ring buoy was 1 1/2 ft too long. rope on the second ring buoy was 8" too short. Both corrected to 1 1/2 the width of the pool or 27 ft.
6.0
16.
Gap in one section of the fence was 4 1/4 inches between vertical members. Gap in another section of the fence was 4 1/2 inches between vertical members. There can be no greater than 4 inches of gap between vertical members. Corrected during the inspection by adding two additional vertical pieces.
4.0
22.
Emergency telephone needs dialing instructions that says " phone dials 911 when picked up". Corrected during inspection.
6.0
General Comments
Signs and safety equipment in place. Emergency phone works. Permit issued. Info on electrical System Safety at Public Swimming Pools was left with the operator.
Some of the depth markings were missing on pool deck. They were replaced by end of inspection. Recommend using tiles cut into pool deck so they do not keep peeling off. All signs on pool deck were in pretty bad shape.