Skimmer lids screwed down as well and unable to remove by guard. Must be removed/removable at permitting inspection. Check the weirs.
0.0
15.
Lifeguard on duty, ring buoy on pool deck has a rope that is short-must be 1 1/2 times width of pool. Pool is 19' wide-Rope should be 28.5' (only 27.5). Replace rope or remove w/ lifeguard on duty. Rope replaced during the inspection w/one that is 28.5. CDI
0.0
29.
Hot water in the restrooms was >120F. Hot water should not be warmer then 110F.
Benches have been moved from the main side wall and spaced on other walls due to covid cautions. There is 1 area that there is ~4 feet between the bench and pool wall. Should have a minimum of 5 feet of clear deck space. Bench should be moved by permitting in 2 weeks.
4.0
General Comments
Rope on the ring buoy is starting to splinter in an area-monitor & replace when in bad repair.
Two of the surface skimmers were plugged in the skimmer even though they had approved equalizer covers on the pool wall. This allows water to enter pipe but not go to the circulation system which can create a hazard. Plugs were removed. -CDI
4.0
23.
The automatic acid feeder continues to pump acid long after the circulation pump is turned off. When the circulation pump are off the automatic feeders must also turn off. Ecolab was contacted and is currently on site to repair, pool closed to bathers during the repair time frame. Acid feeders are now turning off when the circulation pump is turned off -CDI Monitor and test to make sure the feeders still turn off when pumps are off.
4.0
29.
Hot water in the restrooms was 124F. Should not be any warmer than 110F.
At the start of inspection, the pH level was less then a 7.0. Soda ash and Bicarb added to bring the pH up to a 7.0 still. Must stay in a range of 7.2-7.8.
6.0
8.
The inner ring of the skimmers has a black growth/build up on it. Clean to remove and monitor.
4.0
9.
Depth markers are fading or missing part of the unit of measurement "FT". One depth marker is covered up by the chair lift so there is >25 feet b/t depth markers on pool deck. Repair all depth markers and provide a new one by chair lift.
4.0
29.
Hot water in the restrooms was >120F. Should not be any warmer than 110F.
2.0
General Comments
Pool closed until the pH is in a range of 7.2-7.8 and Health Department approved.
The pool water temperature was at 91*F, heated pool water can not exceed 90*F. Temperature to the heated pool water has been turned down.
6.0
29.
The hot water in both restrooms was greater than 130 degrees F. Must be at 110 degrees F.
2.0
General Comments
Therapy pool jets have been turned off until main drains to the jet pump has been replaced. Call Environmental Health when jet main drains are replaced. 919-989-5180
Equalizer lines in the skimmers have been plugged. VGB compliant equalizer covers that are properly sized to handle the gpm flow must beinstalled by April 1st, 2011 and lines unplugged.
4.0
17.
Should have 5 feet of clear walkway around pool deck. Support beam preventing the required walkway.
4.0
29.
Hot water in the restrooms at the lavatories way too hot. Should be a maximum of 110F.
2.0
General Comments
Will return on April 1st, 2011 to verify compliance with the equalizer covers in order to remain in operation. Provide spec. sheets.
Should have 5 feet of clear walkway around pool deck. Support beam preventing the required walkway. Disconnect the hose to handicap accessable chair when not in use to prevent a trip hazard.
4.0
29.
Hot water in restrooms > 120 f should not be >110 f.