Fence has areas that are less then 48" in height. Fence should be a minimum of 48" in height. Fence is constructed prior to 2010 so it is recommended to repair.
Fence is shorter then 48" in height in areas. Should be a minimum of 48".
4.0
17.
Should have a minimum of 6' of clear walkway around pool on deck-chairs are too close to pool.
4.0
19.
The signs are not compliant with .2530 (c). Must have a sign in 4" letters "WARNING NO LIFEGUARD ON DUTY". A sign in 1" letters stating "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" and "ADULTS SHOULD NOT SWIM ALONE". Operator was able to make the signs and post.
New NO DIVING markers were installed on the pool deck-there is an area where there is more then 25' between the markings. Operator was able to locate stencil and paint to add an additional NO DIVING on deck. CDI
4.0
19.
There was not a sign in 1" lettering that stated "CHILDREN SHOULD NOT USE THE SWIMMIMG POOL WITHOUT ADULT SUPERVISION". Operator was able to create one in 1" lettering.
4.0
General Comments
Monitor the ring buoy, rope is showing age. replace once in bad repair.
Fence is starting to sag in areas causing it to only be 47". Fence should be 48" tall minimum. Pool was constructed prior to 2010 so it is not mandated to repair, suggest suggested.
4.0
General Comments
*Unable to inspect the pump and chemical room due to operator being unavailable *
Offsets of greater than 1/2" need to be repaired so that they are not a trip hazard. Area outside of 6' around the pool have offsets close to 1/2". Monitor/repair as needed.
4.0
23.
Chlorine must be fed to the pool automatically using a NSF approved chlorinator. Hand feeding of granular chlorine or skimmer sticks is not an approved method of chlorine delivery.
4.0
25.
Store all pool chemicals in the chemical room separate from pump equipment.
2.0
General Comments
Monitor depth and no diving markers for fading. Monitor gate and ensure a max gap of 2" is maintained under gate. Chlorinator must be installed to obtain permit. Call for reinspection. Contact building inspections for electrical permit/inspection due to pump/motor change.
Include daily checks on main drain covers in record book.
0.0
8.
Equalizer lines have been plugged on pool wall to eliminate a suction hazard. VGB approved covers/grates will be required by 2010 operating season. Do not place chlorine tabs in skimmer baskets when in operation.
4.0
General Comments
Lights in pool operational, if night swimming is allowed then 10fc of light is required on deck.
Letter from Wise Engineering stating compliance with VGB and May 1, 2010 ASME/ANSI standards received and approved.