Location: 2491 US 70 E SMITHFIELD, NC 27577 Facility Type: Seasonal Swimming Pools Inspection Date: 08/30/2019
Score: 34
#
Comments
Points
2.
Free chlorine is measuring at 0 ppm. Chlorine must be maintained at 1.0 ppm
6.0
3.
pH is less than 7.0. Pool pH must be 7.2-7.8.
6.0
8.
Surface skimmers are not able to operate correctly due to level of water in the pool. Pool water is lower than the skimmer. Fill pool to allow skimmers to operate correctly.
4.0
11.
Treads on ladder steps is over 6 inches away from pool wall. Should be between 3 inches and 6 inches away from pool wall. Pool built in 1970.
2.0
16.
Fence was less than 48" in some places. Fence was built in 1970's and meets regulations for that year's code.
4.0
23.
automatic chlorinator is not operating correctly. No chlorine sticks in the skimmer baskets at inspection but evidence shows chlorine sticks have still been used in the skimmers. Strong chlorine small in skimmers with 0 ppm of chlorine in pool. automatic chlorinator must be repaired and functioning at all times.
4.0
24.
Flow meter is not operating. repair or replace.
4.0
25.
Store chlorine in separate chemical room on the premise.
2.0
29.
Pool should have restrooms and a shower at pool area.
2.0
General Comments
1. Water is slightly cloudy. Drains can be seen from pool deck. work on pool clarity. 7. Algae has been removed. Walls have some debris in need of cleaning. Pool floor has some cracks. 9. Recommend to add an 8Ft depth marker on the fence between the other two markers. 13. Contrasting band on steps should be repainted before next pool season. Must call for reinspection to reopen. Permit suspended.
Location: 2491 US 70 E SMITHFIELD, NC 27577 Facility Type: Seasonal Swimming Pools Inspection Date: 07/30/2019
Score: 26
#
Comments
Points
5.
Weekly readings of cyanuric acid and total alkalinity must be recorded.
4.0
7.
Algae present on pool walls and floor. Clean to remove algae.
4.0
11.
Treads on ladder steps is over 6 inches away from pool wall. Should be between 3 inches and 6 inches away from pool wall. Pool built in 1970.
2.0
16.
Fence was less than 48" in some places. Fence was built in 1970's and meets regulations for that year's code.
4.0
23.
Chlorine sticks were placed in all skimmers under the baskets. Chlorine must be added to the pool through an automatic Chlorinator. Chlorine sticks/tablets are not allowed to be left in skimmers. Sticks were removed by inspector at inspection. 30 day intent issued.
4.0
24.
Flow meter is not operating. Repair or replace within 30 days.
4.0
25.
Store chlorine in separate chemical room on the premise.
2.0
29.
Pool should have restrooms and a shower at pool area.
2.0
General Comments
9. It is recommended to add one more 8 FT depth marker on the fence in the back corner. Currently meets 25' requirements. 30 day intent issued.
Location: 2491 US 70 E SMITHFIELD, NC 27577 Facility Type: Seasonal Swimming Pools Inspection Date: 06/29/2018
Score: 12
#
Comments
Points
2.
The free chlorine level was less than 1ppm. Granular chlorine added and allowed to circulate- now 5ppm. Must be a minimum of 1ppm.
6.0
11.
Treads on ladder steps is over 6" away from pool wall. Should be between 3" and 6" away from pool wall.
2.0
25.
Chemicals should be stored in a separate locked storage room.
2.0
29.
Pool should have restrooms and a shower at pool area.
2.0
General Comments
Invoice/letter from licensed electrician stating removal of all electrical wiring to pool light provided. Pool light opening covered and sealed e/ epoxy.
Location: 2491 US 70 E SMITHFIELD, NC 27577 Facility Type: Seasonal Swimming Pools Inspection Date: 06/30/2015
Score: 18
#
Comments
Points
7.
It appears that a dark green/black build up is growing at wall & floor joint. This must be repaired/cleaned by 7/30/15.
4.0
8.
Skimmers should have equalizer lines.
4.0
10.
Bouys on safety rope cannot be spaced more than 5 feet away on rope.
2.0
15.
Ring buoy has a large tear in the cover. Replace the buoy immediatly - closed until complete and approved to reopen by Health Dept. Rope must be 1 1/2 times width of pool.
6.0
29.
Should have shower and restrooms within 300 feet of bather entrance.
Location: 2491 US 70 E SMITHFIELD, NC 27577 Facility Type: Seasonal Swimming Pools Inspection Date: 05/26/2011
Score: 8
#
Comments
Points
8.
Surface skimmers should have equalizer lines. Also keep floating debris out of pool.
4.0
10.
Hook for safety rope should be recessed into wall.
2.0
25.
Should have seperate room for storing chemicals.
2.0
General Comments
Will need to check pool deck area for proper lighting. Must have 10Foot candles of light for night swimming. Keep an eye on cracks on pool deck close to edge of pool wall.